800-720-5256 |
Specializing in Custom, Special, and Hard to Find T-3 Lamps |
|
|
|
SF & SFA Heaters
Anderson Thermal Devices, type SF/SFA, infrared 
heaters, are highly efficient, fast response, medium wavelength heaters for a wide
variety of industrial process heating applications.
|
Rugged stamped foil element strips are mounted
on a high temperature insulation board. The energy
freely radiates to the product without any quartz or ceramic
to block the energy. This allows a 90% conversion of electrical
power input to useable radiant output, eliminates thermal lag for very tight process control, and minimizes stored heat which causes damage to products on shutdown.
|

|
|
Type SFA heaters include 100 air jets per square foot which provide air impingement to assist in drying and provide instant cooling shutdown.
|
 |
 |
Type SF heater (without air jets) and elements running across machine direction. |
 |
SF Heater (without air jets) with elements running in machine direction. |
Standard SFA & SF Heater Sizes ***
NOMINAL*
HEATED
AREA |
ACTUAL** |
VOLTS |
MAXIMUM
HEATER
WATTS |
| |
|
|
|
| 12 X 12 |
12 X 15 |
240 V |
4600 |
| 12 X 24 |
12 X 27 |
240/480 V |
9190 |
| 12 X 36 |
12 X 39 |
480 V |
12220 |
| 12 X 48 |
12 X 51 |
480 V |
18380 |
| 12 X 60 |
12 X 63 |
480 V |
21360 |
| 12 X 72 |
12 X 75 |
480 V |
27580 |
| 12 X 84 |
12 X 87 |
480 V |
29850 |
| 12 X 96 |
12 X 99 |
480 V |
32250 |
|
Nominal SF depth: 4 1/2" Nominal SFA depth: 7 1/2" |
* Nominal size indicates the actual case width and actual heated element length. As an example:
12 x 24 is 12 inches wide and a 24 inch heated length element. |
| ** Actual size indicates the actual outside dimensions of the heater case. |
| *** Custom sizes available on request. |
| DESIGN FEATURES
- Medium wavelength energy readily absorbed by most products
- Available with replaceable type K thermocouples
- Element temperatures up to 2000 F
- Typical wattage range of 20-50 WSI (30-70 WLI)
- Modules available in widths of 4" - 48" & any length needed
- Can be mounted in any Plane; no element sag, no coil creep
- Voltages from 110 V through 600 V
- Responds to output changes in less than 10 seconds
- Elements are easily replaceable in the field |
- Rugged modules constructed of aluminized steel, aluminum extrusion, or stainless steel
- Standard 5' high temperature leads in flexible metallic conduit
- Self cleaning
- Available with multiple zones in a module
- Elements can run parallel to length or to width
- When run in machine direction, elements are skewed to eliminate cold spots or stripping
- Available with through hole for infrared thermometer
- Long trouble free life
- Stainless steel face screen
protects heater face |
Excellence In Infrared Components TM
High Quality Engineering | Excellent Pricing | Quick Delivery
info@andersonthermal.com